Driver Microstep 2CM560
- 50V - 6A
- 8 levels of current adjustment from 1.8~6A
- 15 levels of resolution from 200~25,600 steps
- Inputs (Pulses/Dir or CW/CCW) 5~24V optocoupled with internal limiting resistor, TTL compatible
- Pulse input frequency up to 400KHz
- Motor parameters self-identification system
- Automatic current reduction in case of inactivity
- Overvoltage and overcurrent protection
Internal Reference:
2CM560
Digital Micro-step Driver 2CM560
- 8 settable current level 1~6A
- 15 subdivision levels 200~25 600 steps
- Inputs (Pulses/Dir or CW/CCW) 5~24V opto isolated, TTL signal compatible
- Input frequency up to 400kHz
- Support parameter self-adaptive function
- Automatic half-current function
- Test-running
- Over voltage and over current protection function
- Micro-step filter function can smooth input pulse to reduce trasient motion of motor, make sure motor run more smoothly.
- Nema 23 and Nema 24 motors compatible
Item | Description |
---|---|
Input Voltage | 24~50VDC |
Overvoltage protection | 85VDC |
UnderVoltage protection | 15VDC |
OverHeat protection | 80°C (Temperature of Thermistor) |
Phase current (peak) | 1.8/2.4/3/3.6/4.2/4.8/5.4/6 A – 8 settable values |
Subdivision | 200~25600 Pulses / revolution, 15 subdivision levels in total |
Adaptable Motor | Nema 23 et nema 34 |
Input Signals | PLS (CW) - DIR (CCW) – FREE – Input voltage: 5~24VDC – Input current: 8mA@5VDC / 12mA@24VDC |
Control Mode | Pulse control : PLS + DIR – CW/CCW |
Output signal | ERR - open collector output - maximum current: 100mA |
Operation Indicator | Combination of RUN and ERR Led indicates different status |
Protection Circuit | Over voltage – Under voltage – Over current – Over heat |
Cooling method | Nature air cooling |
Operation environnement | Indoor - installed in the environnement free from direct sunlight – dust – corrosive gas – combustible gas – oil mist – steam and drip |
Operation humidity | <85%RH – non-condensing or water drops |
Operation temperature | 0°C~40°C |
Storage temperature | -20°C~70°C |
Protection | IP20 |
Subdivision setting (Unit : Pulses/Rev.) | Current setting (Unit:A) | ||||||||
---|---|---|---|---|---|---|---|---|---|
SW1 | SW2 | SW3 | Si SW4=ON |
Si SW4=OFF |
SW6 | SW7 | SW8 | RMS | Pointe |
ON | ON | ON | 200 | 1000 | ON | ON | ON | 4.2 | 6 |
OFF | ON | ON | 400 | 2000 | OFF | ON | ON | 3.8 | 5.4 |
ON | OFF | ON | 800 | 4000 | ON | OFF | ON | 3.4 | 4.8 |
OFF | OFF | ON | 1600 | 5000 | OFF | OFF | ON | 3 | 4.2 |
ON | ON | OFF | 3200 | 8000 | ON | ON | OFF | 2.5 | 3.6 |
OFF | ON | OFF | 6400 | 10000 | OFF | ON | OFF | 2.1 | 3 |
ON | OFF | OFF | 12800 | 20000 | ON | OFF | OFF | 1.7 | 2.4 |
OFF | OFF | OFF | 25600 | NA | OFF | OFF | OFF | 1.3 | 1.8 |
Function | DIP setting | Description |
---|---|---|
PLS + DIR | SW6 & SW7 = ON – Others OFF | Set DIP switches according to functions required when power OFF. Power On driver : RUN Led blinking is GREEN & ERR Led is RED. It means settings takes effect. Then Power OFF driver – reset subdivision and current for normal use. |
CW/CCW | SW7 & SW8 = ON – Others OFF | |
Micro-Step smooth & dynamic filter disable | SW5 & SW6 = ON – Others OFF | |
Micro-Step smooth filter enable | SW5 & SW7 = ON – Others OFF | |
Micro-Step dynamic filter enable | SW5 & SW8 = ON – Others OFF | |
Test motor parameter upon power on disable | SW6 & SW7 & SW8 = ON – Others OFF | |
Test motor parameter upon power on enable | SW5 & SW6 & SW7 = ON – Others OFF | |
Test-running | SW6 & SW8 = ON – Others OFF | Motor running @80RPM |
Automatic half-current | SW5 = ON – Others OFF | Set SW5=ON to enable automatic half-current. Phase current will reduce to half of the set value after motor stops for 1.5s |
Accessories
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
Specifications
Brand | Kinco |
Max. Voltage | 50 V |
Max. current | 6 A |
Resolution setting | DIP-switches |
Weight | 280 gr |
Suggested alternatives: Compare
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.